The precautions for regular startup of a super silent generator are essential to ensure the safe and stable operation of the device. To ensure the safe operation of an ultra quiet generator during regular start-up, the following precautions should be taken:
1. Pre check of super silent generator:
Before starting, a detailed pre check should be conducted on the unit. This includes checking whether there are any debris obstructing the surface and surroundings of the unit, whether the air intake and exhaust channels in the machine room (box) are unobstructed, whether the coolant level in the water tank is normal, whether the air filter indicator is normal, whether the lubricating oil level is within the normal range, whether the fuel valve is open and ensuring that fuel is supplied to the engine normally, and whether the battery cable is connected correctly.
2. Preparation for starting the super silent generator:
Ensure that the power generation load equipment is ready. When the generator is directly loaded, the circuit breaker must be disconnected before starting.
3. Super silent generator specification startup:
After powering on, select the idle/full speed switch of the unit to start. The starting time should be controlled within 5 to 10 seconds as much as possible, and the duration should not exceed 30 seconds, in order to prolong the use time of the starting motor and battery. If the first start-up fails, wait for the alarm to be cleared and the unit to return to normal before proceeding with a second start-up.
4. Operation observation:
After the unit enters the operating state, the operator should regularly observe and understand the operating conditions of the unit, such as whether the unit is running normally, whether the instrument indications on the control screen are in the normal position, whether there are pre alarm indications on the control screen, the fuel level in the fuel tank, etc., and regularly record the operating parameters of the unit.
5. Cooling water addition for super silent generator:
Before starting, ensure that sufficient cooling water is added to the generator set to avoid adding it again after the ultra quiet generator catches fire, in order to prevent damage to the body parts caused by rapid heating.
6. Start interval and oil pressure:
The time interval between two starts should not be less than 2 minutes to avoid overheating and burning of the starting motor in the electrical system. Within 15 seconds after starting, the oil pressure displayed on the oil pressure gauge must be higher than the required low pressure, otherwise the machine should be stopped immediately for inspection.
7. Lubrication and preheating of super silent generator:
Before loading, idle for 3-5 minutes. For the chiller, gradually increase the speed to ensure sufficient oil lubrication in all parts.
Following the above precautions can ensure the safe startup and operation of the super silent generator.